Product Introduction 2.1.1 The AE1000A Arteriosclerosis Detection Instrument is a non-invasive hemodynamic testing device used for the early screening of structural and functional lesions in human arterial blood vessels.
2.1.2 During the same cardiac cycle, it collects ECG, heart sounds, and pulse wave signals from the limbs to calculate the pulse wave conduction velocity (baPWV) to assess the degree of vascular hardening; it also synchronously applies pressure to the limbs and measures blood pressure in the limbs to calculate the ankle-brachial index (ABI) to evaluate the degree of narrowing and blockage in the lower limb arteries. 2.1.3 Main application departments: Cardiovascular Medicine, Health Examination Center, Vascular Surgery, Endocrinology, Neurology, Hypertension Department, etc.
Product Features 1. Convenient operation; no manual intervention is required after starting the check, and reports are generated automatically;
2. Comprehensive medical record management, allowing for multiple checks on the same patient and providing appointment functionality;
3. Case data review function, enabling users to easily browse case data;
4. Diagnostic results are generated automatically, and users can choose diagnostic terms to edit the results;
5. Provides ABI/PWV reports and exercise load reports, rich in content with clear results.
Product performance Safety features
Electric shock protection type: Class I device
Level of electric shock protection: BF type
Ingress protection level: IPX0
Operating mode: Continuous operation
Input power: ≤20 VA
Power supply: Input voltage 100-240 V
Frequency: 50/60 Hz
ECG specifications
Frequency response (bandwidth): 0.67 Hz to 40 Hz (-3 dB, 110%)
Common mode rejection ratio: ≥89 dBInput impedance: ≥2.5 MΩ
Heart rate measurement range: 30 bpm to 300 bpm
Heart rate accuracy: ±1% or ±1 bpm, whichever is greater
High T wave suppression capability: 1 mV
NIBP specifications
NIBP measurement range (mmHg)
Systolic pressure: 60 mmHg to 255 mmHg
Mean pressure: 40 mmHg to 235 mmHg
Diastolic pressure: 30 mmHg to 220 mmHg
NIBP measurement accuracy
Maximum mean error: ±5 mmHg
Maximum standard deviation: 8 mm
HgStatic pressure measurement range: 0 mmHg to 297 mmHg (0 kPa to 39.6 kPa)
Static pressure measurement accuracy: ±3 mmHg (±0.4 kPa)
Resolution: 1 mmHg (0.133 kPa)
Attachment Sleeve bands (1 for right arm, 1 for left arm, 1 for right ankle, 1 for left ankle)
ECG lead wires
ECG clips (1 red, 1 yellow)
Stethoscope probe
PCG weighting
Power cord
Ground wire
USB data cable
Double-tube (2 pieces)
Dongle (module scheme not applicable)
Instruction manual
Physical Characteristics Host Dimensions(Length × Width × Height): 248 mm × 163 mm × 57 mmHost
Weight: Approximately 1.7 kg (excluding accessories)