Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Multiparameter Simulator |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Project | Name | Description | |
1 | IBP1 port | Used to connect IBP1 cable plug. (Refer to "IBP Line Orders") | |
2 | IBP2 port | Used to connect IBP2 cable plug. (Refer to "IBP Line Orders") | |
3 | IBP3 port | Used to connect IBP3 cable plug. (Refer to "IBP Line Orders") | |
4 | IBP4 port | Used to connect IBP4 cable plug. (Refer to "IBP Line Orders") | |
5 | C.O./TEMP port | The port is temperature port at present. Note: if you use this port, plugged the body temperature cables before turned on the simulator. |
|
6 | USB port | Reserved port | |
7 | Reset port | Switch the simulator. | |
8 | TF port | Plug SD card. Note: If use the SD card, you need to put the SD card into the simulator before turning it on. |
|
9 | Equivalent power jack | According to the instructions of our company's power supply. | |
10 | 10-lead jacks | Output to 10 Universal ECG Jacks, color-coded to AHA and IEC Standards. | |
Label | Meaning | ||
RA or R | Right arm | ||
LA or L | Left arm | ||
RL or N | Right leg(reference or grounded) | ||
LL or F | Left leg | ||
V1, V2, V3, V4, V5 and V6 | V Leads (U.S. and Canada), also referred to as pericardial, precordial or unipolar chest leads. | ||
C1, C2, C3, C4, C5 and C6 | Chest leads (International) | ||
11 | The indicator light of charging |
Charge indicator light is red : AC power supply / charging. Green : full electricity. Red and flashing: battery low. |
|
12 | Display | The display shows the selected code, the meanings of the code, the waveforms, the list of the functions, System Setting and so on. | |
13 | Keys | There are two kinds of keys: the numeric keys and function keys. | |
0 | View the current settings. | ||
1 | Normal sinus rhythm, 80BPM, 1mV. | ||
2 | Set the ECG Rate: 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM. | ||
3 | Set amplitude: 0.5, 1.0, 1.5 and 2.0 mV. | ||
4 | Set the respiratory Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80,100, 120 and 150 R/MIN. | ||
5 | Set the baseline impedance : 500, 1000, 1500 and 2000Ω. | ||
6 | Set the respiratory impedance : 0.2, 0.5, 1.0 and 3.0 Ω. | ||
7 | Channel 1, 2,3 and 4 will be reset to 0. | ||
8 | Set all the channels as IBP waveform. | ||
9 | Set all the channels as static-pressure level. | ||
14 | Control keys | ||
Up and down keys | When select a key which can adjust a setting, you can click the up and down keys to adjust it. | ||
Left and right keys | Switch the pages and browse the codes. | ||
Enter | Determine the choice. | ||
CLEAR | Cancel the current selection, select the code again. | ||
On/Off | Long press the key to turn on or turn off the simulator. |
Item | Quantity |
Standard components: | |
User Manual (print version) | 1 |
15V adapter or 9V adapter ( USA Porduction) | 1 |
Optional Accessories: | |
Temperature Cable | 1 |
IBP Cable | 1 |
Case Convertion Software and Operating Introduction | 1 |
For more information, please contact your local dealer. |