Model:CMS8000 Introduction:
Handheld patient monitor Standard parameters: ECG,SPO2,NIBP,RESP,TEMP,PR
Optional parameters: 2-IBP,ETCO2,thermal printer,VGA,12-channel ECG,trolley,central monitor system
Features:
-Display mode: 12'' color TFT LCD with high-resolution.
-Be applicable for adult, pediatric and neonatal for all-round monitoring.
-Operation interface with Chinese and English. (Optional languages: French, German, Italian, Turkish, etc.)
-Multiple display modes are optional, such as big characters interface.
-Waveform and data colour can be set optionally.
-Storage of 480-hour trend data, and review of 40-second holographic waveform.
-7-lead ECG displays in a screen, and ECG waveforms series display.
-Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).
-Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability.
-Function of NIBP review, storage for up to 400 NIBP data.
-Connect central monitoring station, other bed observation and software updating with wireless and wired mode.
-Built-in SD card, U disk for storing data and U disk updating.
-Support the functions of VGA video output and adjustable LCD backlight.
-Support alarm with human voice body.
-Function of synchronous signal output.
-Three operation modes: monitoring, surgery and diagnosis.
-Auto-analysis for arrhythmia waveform.
-Calculation function for drug concentration and titration table.
-Dual-channel temperature monitoring, and with temperature error display.
-NIBP dual-overpressure protection with software and hardware.
-Built-in thermal printer.
-Built-in rechargeable lithium battery for uninterrupted monitoring.
Performance:
-ECG Lead Mode 3-lead and 5-lead are optional
-Lead Selection I, II, III, avR, avL, avF, V
-Gain Selection ×0.25, ×0.5, ×1, ×2
-HR Range 15 ~ 300 bpm
-Measuring and Alarm Range for ST Segment -0.6 mV~ + 0.8 mV
-Scan Speed for ECG Waveform 12.5mm/s, 25mm/s, 50mm/s
RESP
-Measuring Method R-F(RA-LL) Impedance
-Measuring and Alarm Range for Resp. Rate:
-Adult 0~120rpm
-Pediatric and Neonatal 0~150rpm
-Apnea Alarm 10 ~ 40 S
SpO2
-Measuring Range 0 ~ 100 %
-Accuracy 70% ~ 100% ±2%; 0% ~ 69% unspecified
-Measuring range for pulse rate 0~250bpm
-SpO2 probe SpO2 probe for adult, pediatric and neonatal are optional
NIBP
-Method Oscillometry
-Mode Manual, Auto, Continuous
-Measuring Period in Continuous Mode 5 Min
-Measuring and Alarm Range 10~270mmHg
-Overpressure protection dual-protection with software and hardware
-Cuff cuff for adult, pediatric and neonatal are optional
TEMP
-Channel dual-channel
-Measuring and Alarm Range 0 ~ 50°C
-Resolution 0.1°C
-Accuracy ±0.1°C
EtCO2(optional)
-Method Sidestream or Mainstream
-Measuring Range for CO2 0~150mmHg
-Resolution for CO2:
-0.1 mm Hg 0 to 69 mm Hg
-0.25 mm Hg 70 to 150 mm Hg
-Accuracy for CO2:
-0 40 mm Hg ±2 mm Hg
-41 70 mm Hg ±5%
-71 100 mm Hg ±8%
-101 150 mm Hg ±10%
-Respiration Rate>80BPM ±12%
-AwRR Range 2~150 rpm
-AwRR Accuracy ±1BPM
-Apnea Alarm Available
IBP(optional)
-Channel dual-channel
-Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
-Measuring and Alarm Range -50~350 mm Hg
-Resolution 1 mm Hg
-Accuracy ±2% or 1mm Hg, which is greater
Recorder(optional)
-Print Mode thermal array
-Recording Width 48mm
-Paper Speed 25mm/s, 50mm/s
-Quantity of Printing Waveform dual-channel
-Physical characteristic:
-Requirement of power AC 100~240V, 50/60Hz
-Power consumption 150VA
-Dimension 310×140×263(mm)