1) Input mode offers both floating capability and defibrillation protection, ensuring safety and reliability during use.
2) Standard 12-lead setup guarantees comprehensive data acquisition for precise diagnostics.
3) Patient safety is paramount, with patient leak current maintained at less than 10 µA.
4) High input impedance of ≥ 2.5 MΩ ensures accurate signal reception and reliability.
5) Enjoy an expansive frequency response range of 0.01Hz-300Hz (-3dB) for capturing detailed signal information.
6) The time constant is optimized at ≥ 3.2 seconds for superior performance and accuracy.
7) Exceptional CMRR rating of > 105 dB provides enhanced signal clarity by effectively minimizing noise.
8) Robust filtering capabilities include power frequency (AC 50/60 Hz), EMG (25 Hz/35 Hz (-3 dB)), and baseline drift filters for optimal signal integrity.
9) Utilize our advanced thermal printing system for precise and reliable ECG recording.
10) Paper size: Precision defined at 210 mm (W) × 20 m (L), utilizing high-speed thermal paper for seamless and efficient printing.
11) Paper speed: Versatile options available at 5 mm/s, 6.25 mm/s, 10 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s, with an accuracy of ± 5 % for precise output.
12) Gain (sensitivity): Adjustable settings at 2.5, 5, 10, 20, 40 mm/mV, ensuring accuracy of ± 2 %, allowing for tailored sensitivity adjustments.
Standard sensitivity: Precisely calibrated at 10 mm/mV ± 0.2 mm/mV for consistent and reliable measurements.
13) Record mode: Offers flexibility with auto, rhythm, and manual record modes to suit diverse user needs.
14) Measurement parameters: Comprehensive metrics including HR, P - R interval, P Duration, QRS Duration, T Duration, Q - T interval, Q - Tc, P Axis, QRS Axis, T Axis, R (V5) amplitude, S (V1) amplitude, R (V5) + S (V1) amplitude, ensuring thorough diagnostic capability.
15) Safety class: Classified as class I with defibrillation-proof type CF applied part, prioritizing user safety.
16) Polarizing voltage: Robust tolerance at ± 610 mV, accommodating diverse operational conditions.
17) Noise level: Ultra-low noise threshold at ≤ 12 µVp-p for clear and accurate signal acquisition.
18) Sampling frequency for ECG signal input: High-fidelity capture at 32 kHz, ensuring detailed signal resolution.
19) Sampling frequency for waveform data processing: Effective at 1 kHz to ensure smooth and precise data handling.
20) Sampling accuracy: Advanced 24-bit precision offering exceptionally detailed and accurate data capture.
21) Minimum detection signal: Capable of detecting a 10 Hz, 20 µV (peak-peak value) sinusoidal signal, ensuring a visual recorded deflection.
22) Pacemaker detection channel: Efficient monitoring across all leads for comprehensive pacemaker detection.
23) Accuracy of input signal reproduction: Maintained at ± 5 %, ensuring reliable and consistent data output.
24) Amplitude quantization: Exceptionally refined at ≤ 5µV/LSB for superior signal precision.
25) Time deviation in each channel: Minimized to <100 µs, ensuring synchronized and accurate timing across channels.
26) Power supply:
AC: Wide range compatibility from 100V ~ 240V (50/60 Hz) for global usability.
DC: Powered by a 14.8 V / 5200 mAh rechargeable lithium battery, ensuring long-lasting and reliable operation.
27) Degree of protection against ingress of liquid: IPX0 rating, designed for environments with no significant exposure to liquids.
28) Working mode: Continuous operation to maximize uptime and productivity.